Optical emission spectrum @ 90ns with best fit
Measurement, line fit and continuum background for data taken at 90 ns after the first emission (Figure 3 in paper).
Measurement, line fit and continuum background for data taken at 90 ns after the first emission (Figure 3 in paper).
Spatio-temporal plots for different N2 admixtures of the measured and individually normalized emission at 391 nm [(a) - (c)], of the time modulated component of the data shown in the first row [(d) -
Normalized (to the maximum value of each data set) spatio-temporal emission plots obtained from wavelength integrated and wavelength selective PROES (columns) at various N_2 gas flows (rows).
Emission spectra for the 8.5 m cable experiment at time intervals of 30 ns. 1st column is the wavelength. (Fig. 8b in the paper)
Emission spectra for the 3.4 m cable experiment at time intervals of 30 ns. 1st column is the wavelength. (Fig. 8a in the paper)
The time-resolved emission spectra of the first 34 ns after plasma ignition for a nanosecond pulsed plasma with approximately 15 ns width and 2-3 ns rising times at 20 kV and 15 Hz.